Ac Freon Leak Repairs


During the summer months one of the most common problems with Air Conditioning systems has grown into low on freon. This is a problem that normally ends having the Air Conditioning contractor putting a few pounds of freon in and calling it quits. This is not the proper way to solve the salvation, and never a repair understand that last forever. By going through the next steps I have provided in the following paragraphs you can guarantee your air conditioning will work next 365 days.

The way an Air Conditioning system works is by using a refrigerant (freon) and allowing it to change its state to have heat out of the environment. This refrigerant is to the sealed system which should never have to be replaced or charged up. When a proper laying out an air conditioner is performed the contractor should find a vacuum on the answer check for any leakages. If there is a leak in the system it should be found and solved. This is where the case normally comes into have an affect on. during the installation process either someone had a bad braze weld or didn't add a vacuum pump on as there are a leak.

This leak could go undetected for several years and by the time the customer notices it there is no more warranty on an item or installation. When another contractor comes in to determine the problem they just fill it up and take the huge income. This charge to fill with freon can range from $350-$675 and soon after a few times the current market can spend more than system is worth. And lastly damage the low freon can do to your compressor which cause future problems.

The proper thing to do regarding a loss of freon really is easy, and after the fix you can be sure that you will definitely not lose freon again.

What to avoid this see the contract rod is placed the system into a favorable pressure using nitrogen. By putting that drastically pressure in the system after that you can to hear the nitrogen leak and fix the problem. If the problem is incorporated in the outside or inside coils you may need them replaced. Hopefully the leak was in one of the original welds and simply have to be touched up. After the repair there must be a vacuum put on the system. By bringing the solution to a negative pressure you remove almost all noncondensables and any moisture in regards to the system. Let this vacuum sit for an hour and see for people with any loss. If not recharge to factory standards however you Air Conditioning system will work well for several years.

.

No comments:

Post a Comment